Sectioning and Mounting Protocol

Sectioning and Mounting Protocol

Technovit Glycol Methacrylate: Technical Information and Help From Heraeus Kulzer.

Sectioning

Sectioning is best done with a rotary or sledge microtome such as the JB-4 Microtome. The features to look for are retraction of the specimen on the return stroke and motorized motion of the sample relative to the knife edge. Retraction is needed to keep the hard sample from brushing against the knife edge on the return stroke, damaging the edge and block face. Motorized sample movement is desirable to get more reproducible cutting speed and force.

The best sections are obtained on these microtomes with a glass or tungsten carbide knife. Disposable tungsten carbide knives are available from Energy Beam Sciences which offer the ability to cut routine serial 1 micron thick sections. Dry block faces are used; in fact, moisture and humidity will soften GMA blocks sufficiently to make sectioning impossible. If the block is too soft to section dry the block in a warm oven or move to a less humid work environment.

Sections are collected from the knife edge using tweezers and stretched by floating on a water bath. Two factors are important when preparing the water bath: cleanliness and temperature. Any residue of soap or oil will decrease the surface tension of the water dramatically reducing its stretching ability and/or causing the section to sink. Increasing temperature also reduces the stretching ability of the bath so that at 20° C stretching of 10 - 13% is possible while at 60° C stretching of 7 - 9% is possible. Section stretching allows recovery of almost all the compression caused during sectioning. Properly stretched, much less than 1% of the compression in vertical dimension remains in the sections.

Most procedures call for mounting your sections on slides before staining. The exception may be when staining sawn sections since these retain enough strength to be held in tweezers and hand-dipped in the various staining solutions (followed directly by coverslipping to slides). Mounting thinner sections to slides before staining also helps to prevent folds from developing in the sections. If you are using slides precoated with silane, skip the protocol for coating your own.

Preparing Silanized Slides

Solutions:

The silane material comes in a liquid form from Sigma. The full name is 3,aminopropyltriethoxysilane.

Procedure:

  1. Dip slides in 2% silane/acetone solution for one minute.
  2. Dip slides in 100% acetone for one minute.
  3. Dip slides in double distilled water for one minute.
  4. Repeat step 3 with agitation.
  5. Air dry.
  6. Apply sections on a drop of water on the slide.
  7. Dry on 60°C hot plate for 2 - 5 minutes.
  8. Air dry at room temperature overnight.

These silanized slides can be stored at room temperature for months without any problems.

Source:

Tobias Baskin, Univ. of Missouri, 109 Tucker Hall, Columbia, MO, Email: baskin@biosci.mbp.missouri.edu

Citation:

Angerer, L. M. & Angerer, R. C. (1991) Localization of mRNAs by in-situ hybridization. Functional Organization of the Nucleus: a Laboratory Guide. Methods in Cell Biology, Vol 35, (ed. by B. A. Hamalko & S. C. R. Elgin), pp. 37-71. Academic Press, San Diego.

Mounting

Dip your coated slide into the waterbath under the section and lift the section off the water surface. Dry the slides for about 15 minutes on a 60°C slide warmer.

实验频道录入:Protocol    责任编辑:Protocol 


评论】【收藏】【告诉好友】【打印】 【返回顶部】 【直达首页】 【进入论坛】 【转入博客】  

文章评论(评论内容只代表网友观点,与生物谷立场无关!

关于我们 | 广告服务 | 联系方式 | 帮助信息 | 服务条款 | 法律声明 | 战略伙伴 | 友情链接 | 生意通 | 网站地图 | Bioon English
Copyright © 2001-2007 生物谷 bioon.com , All Rights Reserved. 版权所有
不良信息举报信箱:editor#bioon.com
网站备案:沪ICP备05022939号